Item | Specification | BS-2081L | |
Optical System | NIS60 Infinite Color Corrected Optical System | ● | |
Viewing Head | Seidentopf Trinocular Head, 30° inclined, interpupillary distance: 47mm-78mm; splitting ratio Eyepiece:Trinocular=100:0 or 20:80 or 0:100 | ● | |
Ergo Tilting Trinocular Head, adjustable 0-35° inclined, interpupillary distance 47mm-78mm; splitting ratio Eyepiece:Trinocular=100:0 or 20:80 or 0:100 | ○ | ||
Seidentopf Binocular Head, 30° inclined, interpupillary distance: 47mm-78mm | ○ | ||
Eyepiece | Super wide field plan eyepiece SW10X/25mm, diopter adjustable | ● | |
Super wide field plan eyepiece SW10X/22mm, diopter adjustable | ○ | ||
Extra wide field plan eyepiece EW12.5X/17.5mm, diopter adjustable | ○ | ||
Wide field plan eyepiece WF15X/16mm, diopter adjustable | ○ | ||
Wide field plan eyepiece WF20X/12mm, diopter adjustable | ○ | ||
Objective | N-PLN Plan Objective | N-PLN 2X/NA=0.06, WD=7.5mm | ○ |
N-PLN 4X/NA=0.10, WD=30mm | ● | ||
N-PLN 10X/NA=0.25, WD=10.2mm | ● | ||
N-PLN 20X/NA=0.40, WD=12mm | ● | ||
N-PLN 40X/NA=0.65, WD=0.7mm | ● | ||
N-PLN 100X(Oil)/NA=1.25, WD=0.2mm | ● | ||
N-PLN 50X(Oil)/NA=0.95, WD=0.19mm | ○ | ||
N-PLN 60X/NA=0.80, WD=0.3mm | ○ | ||
N-PLN-I 100X (Oil, with Iris Diaphragm)/ NA=0.5-1.25, WD=0.2mm | ○ | ||
N-PLN PH Plan Phase Contrast Objective | N-PLN PH 10X/NA=0.25, WD=10.2mm | ○ | |
N-PLN PH 20X/NA=0.40, WD=12mm | ○ | ||
N-PLN PH 40X/NA=0.65, WD=0.7mm | ○ | ||
N-PLN PH 100X(Oil)/NA=1.25, WD=0.2mm | ○ | ||
N-PLFN Plan Semi-apochromatic Fluorescent Objective | N-PLFN 4X/NA=0.13, WD=17.2mm | ○ | |
N-PLFN 10X/NA=0.30, WD=16.0mm | ○ | ||
N-PLFN 20X/NA=0.50, WD=2.1mm | ○ | ||
N-PLFN 40X/NA=0.75, WD=1.5mm | ○ | ||
N-PLFN 100X(Oil)/NA=1.4, WD=0.16mm | ○ | ||
Nosepiece | Backward Coded Sextuple Nosepiece (with DIC slot) | ● | |
Condenser | Swing-out type condenser N.A.0.9/0.25 | ● | |
Turret Phase Contrast Condenser | ○ | ||
Dark-field Condenser (Dry), used for objectives lower than 100X | ○ | ||
Dark-field Condenser (Oil), used for 100X objective | ○ | ||
Transmitted Illumination | 3W S-LED lamp, center pre-set, intensity adjustable, with intelligent illumination management system | ● | |
Focusing | Low-position coaxial coarse and fine focusing, fine division 1μm, Moving range 35mm | ● | |
Stage | Double layers mechanical stage, size 190mmX152mm; moving range 78mmX54mm (double slide holder, Right or left handle); precision: 0.1mm | ● | |
Double layers mechanical stage, size 190mmX152mm; moving range 78mmX54mm (double slide holder, Right or left handle); precision: 0.1mm; with Sapphire Crystal Glass Insert | ○ | ||
DIC Kit | 10X DIC Objective Lens | ○ | |
20X DIC Objective Lens | ○ | ||
Polarizer for DIC Kit | ○ | ||
DIC insert plate(10X/20X), can be inserted into the DIC slot on nosepiece | ○ | ||
DIC insert plate(40X/100X) can be inserted into the DIC slot on nosepiece | ○ | ||
DIC Turret Condenser | ○ | ||
Reflected Fluorescent Attachment (with mercury lamp) | Turret with 6 filter block cubes position, with iris field diaphragm and aperture diaphragm, central adjustable; with filter slot; with fluorescence filters (B,G,U,V,R fluorescent filters are available). | ○ | |
100W mercury lamp house, filament center and focus adjustable; with reflected mirror, mirror center and focus adjustable. | ○ | ||
Digital power controller, wide voltage 100-240VAC | ○ | ||
ND6/ND25 Filter | ○ | ||
Reflected Fluorescent Attachment (with LED lamp) | LED Reflected Fluorescent Attachment (Turret with 6-position for filter block cubes, with B, G fluorescent filters, including B,G LED lamps, the attachment has 4 position for the LED lamps) | ○ | |
B, G, U, R LED fluorescent lamps (can be used for B, G, U, R, FITC, DAPI, TRITC fluorescent filters) | ○ | ||
B, G, U, R, FITC, DAPI, TRITC fluorescent filters | ○ | ||
Filter for transmitted illumination | Green Filter 45mm | ○ | |
Blue Filter 45mm | ○ | ||
Yellow Filter 45mm | ○ | ||
Red Filter 45mm | ○ | ||
ND6 Filter | ○ | ||
ND25 Filter | ○ | ||
Other Accessories | 0.5X C-mount Adapter | ○ | |
1X C-mount Adapter | ○ | ||
Dust Cover | ● | ||
Power Cord | ● | ||
Immersion Oil 5ml | ● | ||
Simple Polarizing kit (Polarizer and Analyzer) | ○ | ||
Calibration slide 0.01mm | ○ | ||
Multi Viewing Attachment for 2/3/5/7/10 person | ○ |
BS-2081L
Sapphire Glass Stage is optional. Mechanical stage with sapphire glass insert is optional, it is endurable, never could be scratched and allows users to clear the stage easily.Put Slide by One Hand. It is easy for users to put slides by one hand due to the special designed slide clip.Tilting Trinocular Head is optional. (1) The eye tube can be adjusted from 0°-35°. (2) Digital cameras or DSLR cameras can be connected to the trinocular tube. (3) The beam splitter has 3-position (100:0, 20:80, 0:100). The splitter bar can be assembled on the either side according to user’s requirements.ECO Function The transmitted light would be off automatically after 30 minutes from operators leave. It can not only save energy, but also keep the lamp life longer.Intelligent operating system. (1) Coded Nosepiece with light intensity memory function. The BS-2081L microscope can memorize the illumination brightness when using each objective. When the objective has been changed, the light intensity will be automatically adjusted to reduce visual fatigue and improve work efficiency.Low Position X-Y Knobs. The height of the stage control knobs can be adjusted up or down by 18mm to ensure a comfortable hand position, the tension of X-Y control knob also can be adjusted.(2)Use a dimming knob to achieve multiple functions. One Click: Enter standby status Double Clicks: Light lock or unlock Rotation: Adjust brightness Press + Up-spin: Switch to the upper light source Press + Down-spin: Switch to the under light source Press 3 seconds: Set the time of turning off the light after leaving. (3)The display of microscope working status. The LCD on the front of the microscope can display the working status of the microscope, including magnification, light intensity, sleepy model and so on. (4)Color temperature adjustment function. The color temperature can be adjusted from yellow to white, which can lead to a better contrast and meet the requirements of various research.